Technical Parameters
|
Parameter |
Value |
|
Rated Voltage |
24kV |
|
Continuous Operating Voltage |
20.8kV |
|
Nominal Discharge Current |
5kA (8/20μs) |
|
Residual Voltage (5kA) |
≤85kV |
|
Insulation Material |
EPDM |
|
Adaptable Interface |
Elbow 630A Extension Port |
Protect Your 24kV System from Lightning
The Elbow Surge Arrester is a fully insulated, fully shielded, and touchable zinc oxide arrester for 24kV medium voltage systems. It mounts on the extension port of an elbow connector or loadbreak connector. It protects cable branches, ring main units, and compact substations from overvoltage and lightning. This 24kV Elbow Surge Arrester cannot be connected directly to the equipment bushing.
We are ChangZhou HY Power Electric Co., Ltd. We started production on March 18, 2024. Our factory covers 1,400 square meters. We have 28 permanent employees. Our monthly capacity reaches over 500 cable accessory units. We have our own R&D team. We invest over 3% of our sales revenue into R&D each year. We are recognized as a Changzhou City Enterprise Technology Center.
Why 24kV Systems Need Surge Protection
24kV distribution systems cover larger areas. They have longer lines. This means they face a higher risk of lightning strikes. Surge arresters are essential for protecting distribution equipment and cables. When overvoltage occurs, the zinc oxide varistor in this 24kV Elbow Surge Arrester conducts quickly. It discharges the energy to the ground. The residual voltage stays below the equipment insulation level. This protects your devices and cables from damage. The arrester responds fast and gives reliable protection.
Durable Construction for Harsh Conditions
The 24kV Elbow Surge Arrester uses EPDM rubber as insulation material. It is fully shielded and touchable. The protection level is IP68. You can bury it or use it long-term in high humidity environments. It fits the 630A extension port of the elbow connector or loadbreak connector. Installation is simple. Just plug it in. The nominal discharge current is 5kA (8/20μs). Residual voltage does not exceed 85kV for 24kV systems. The continuous operating voltage is 20.8kV. This 24kV Elbow Surge Arrester complies with GB/T11032 standards.
Quality Assurance and Service
All purchased parts go through our quality inspection department. During production, workers do self-inspections. Quality inspectors do spot checks. Before shipping, each 24kV Elbow Surge Arrester gets a full inspection. We accept third-party inspections. We support OEM and ODM services. The minimum order quantity is 1 unit. Standard products take 25 working days. We offer a one-year warranty. Export packaging uses three protective layers. If damage occurs, we send replacement parts based on the situation.